5
Installation
Use 18 AWG wire for speed adjust potentiometer wiring.
Size the DC voltage input and motor wire according to the
following chart:
Table 1. Wire Gauge/Length Chart
Armature Current Wire Gauge Maximum Wire
(amps) (AWG) Length (feet)
0 19 14 8
20 32 10 10
60 8 10
Wiring
Warning
Do not install, remove, or rewire this equipment with power
applied. Failure to heed this warning may result in fire,
explosion, or serious injury.
This drive is isolated from earth ground. To prevent the
risk of injury or fatality, avoid direct contact with the printed
circuit board or with circuit elements.
Do not disconnect any of the motor leads from the drive
unless power is removed. Opening any one motor lead
may destroy the drive.
This drive is not diode-protected from reverse battery
voltage. You must assure that POS (+) is wired to +VDC
IN and NEG () is wired to VDC IN.
Vista de página 10