The FHP Series PCM Adder Board 175324.00 accepts a 0 - 5 VDC, 0 - 10 VDC, or 4-20
mA signal and outputs an isolated 0-5 VDC signal without requiring additional panel
space. It mounts directly over the main AC board (bottom board) thus maintaining the
same footprint. This instruction manual will give you step-by-step information for
successfully mounting the PCM Adder Board to your FHP Series drive.
The following diagram shows a FHP Series drive with the PCM adder board installed onto
the unit and the parts supplied in this kit.
MOUNTING INSTRUCTIONS
FOR FHP SERIES PCM ADDER BOARD
6
-PI
N
HEADER
(
1
)
6
-
3
2 x 1
5/
1
6"
PHILLIPS SCREW
(
1
)
0
.
5
7
8
" NYL
ON
S
PACER
(
1
)
S
H
OU
LDE
R
ASHER
1
P
CB
S
TANDOFF
(
2
)
JUMPER
(
1
)
P
C
M ADDE
R
B
OARD
(
1
)
S1
S2
S3
E
1
D
J5
01
1:0-5VD
C
2:0-10VD
C
3
:4-
20M
JMP5
02
:INPUT TYP
E
TB5
01
2-3:
C
URREN
T
1-2:V
O
LTA
GE
PART
SSU
PPLIED IN THI
S
KIT
Re
q
uired Tools: Philli
p
s Screwdriver
MAIN AC BOARD
(BOTTOM BOARD)
TB
501
Y
U
W
J50
1
C50
1
C50
2
TH
50
1
L
1
L
2
230
V
D
JMP5
02
:INPUT TYP
E
2-3:
C
URREN
T
1-2:V
O
LTA
GE
PCM ADDER
BOARD
Vista de página 0
1 2 3 4

Resumo do Conteúdo

Página 1 - MOUNTING INSTRUCTIONS

The FHP Series PCM Adder Board 175324.00 accepts a 0 - 5 VDC, 0 - 10 VDC, or 4-20mA signal and outputs an isolated 0-5 VDC signal without requiring ad

Página 2 - S T E P # 2

2 Leeson FHP Series PCM Adder Board 175324.00 Mounting InstructionsTB501VUWJ501C501C502H501L1L2115V230VUSING A PHILLIPSSCREWDRIVER REMOVESCREW AND PLA

Página 3 - S T E P # 6

3Leeson FHP Series PCM Adder Board 175324.00 Mounting Instructions2TVUWJ501C501C502TH501L1L2115V230VTQINSTALL TWO(2) PLASTICSTANDOFFSONTO BOTTOMBOARDS

Página 4 - S T E P # 7

4 Leeson FHP Series PCM Adder Board 175324.00 Mounting Instructions2100 Washington StreetGrafton, WI 53024-0241, U.S.A.TEL: (262) 377-8810 FAX: (2