18
Speed Adjust Potentiometer Connections
Set JMP504 for VDC input by jumpering pins 1 & 2. Set
JMP505 for 0-5VDC by jumpering pin column 1. Refer to
Figure 4 (page 4) for Jumper Locations. Connect a speed
adjust potentiometer to terminals S1, S2 and S3. Make
sure the potentiometer is connected so that the motor
speed will increase as the potentiometer is turned
clockwise. See Figure 10 below.
NOTE: These settings and connections are factory installed
on the 175326.00 drive.
Figure 10. Speed Adjust Potentiometer
Connections to TB501 for 175326.00
D
S3
S2 S1 E1
E2
1
0
K
O
HM
S
PEED AD
JUST
P
O
TENTI
O
METE
R
C
W
TB501
Vista de página 26